Design Three Phase Overcurrent Relays Based on Microcomputer

Main Article Content

Mohammed Y. Suliman
Amer M. Kado

Abstract

A new design of three phase overcurrent relay described in this paper. The performance of the new design shows the ability to obtain any shape of characteristic with high accuracy and distinguish between transient and steady state fault. This design used more precise and flexible model Sachdev linear model for get any characteristic, also fast measurement theory to measure load current for less than half cycle and good hardware system design controlled by Pentium version 4 processor.

Metrics

Metrics Loading ...

Article Details

Section
Articles

Plaudit

References

Dinesh Birla and Rudra Prakash Time- Overcurrent relay Coordination”, International Journal of Emerging Electric Power Systems, vol. 2, Issue2 2005. DOI: https://doi.org/10.2202/1553-779X.1039

Sutherland P. E., Protective Device Coordination in an Industrial Power System with Multiple Sources , IEEE Transactions on Industry Applications, Vol.-33, No.-4, pp. 096-1103, July/August 1997. DOI: https://doi.org/10.1109/28.605753

IEEE Committee Report Computer representation of overcurrent relay characteristics , IEEE Trans. On Power Delivery, vol.4 No. 3, pp1656-67. Jul 1989. DOI: https://doi.org/10.1109/61.32656

H. Zeineldin, E. El-Saadany, A novel problem formulation for overcurrent relay coordination , IEEE LESCOPE Conference, vol. 1, July, 2004, pp. 48 52.

C. Brezinski, Numerical Analysis: Interpolation and extrapolation , Vol. II, 2000. DOI: https://doi.org/10.1016/S0377-0427(00)00352-6

George W. Collins, Fundamental Numerical Methods and Data Analysis , 2003.

H.A. Abyaneh, M. Al-Dabbagh, A new optimal approach for coordination of overcurrent relays in interconnected power systems , IEEE Trans. Power Deliv. 18 April 2003,pp 430 435. DOI: https://doi.org/10.1109/TPWRD.2002.803754

GE Power Mangement “Tow vs. Three overcurrent Elements for Phase Fault Protection in Feeder Relays” Technical Notes, 2000.

Arturo Conde, Emesto Vazquez, A Time Overcurrent Adaptive Relay , International Journal of Electrical Power and Energy Systems, Vol.-25, Issue-10, pp. 841-847, December 2003. DOI: https://doi.org/10.1016/S0142-0615(03)00059-0

Mohammed Y., Controlling of Multiple Relay Based on Microcomputer , thesis, University of Mosul, Mosul, 1997.

Abdul Saha and Abbas, Microprocessor based fast system for measuring power, power factor, frequency and peak amplitude of voltage and current of sinusoidal signal ,IE(I) Journal-ET vol.69,feb 1989,pp56-58.

Similar Articles

You may also start an advanced similarity search for this article.