Electrolytic Production of Potassium bromate Using Graphite Substrate Lead dioxide (GSLD) Anode
Main Article Content
Abstract
Graphite substrate lead dioxide (GSLD) was used to make a suitable anode for the production of potassium bromate from potassium bromide. This anode has been used successfully in the presence of certain addition agents (like potassium dichromate) as a replacement for graphite anode. A laboratory electrolytic cell was designed to produce of potassium bromate. A solution of potassium bromide (240 g/l) and potassium bromate (20 g/l) is electrolyzed in batch wise. The effect of anodic current density, temperature, and starting PH of electrolyte on the current efficiency of bromate formation was studied. High current efficiency of about 92 – 94 % was obtained by using (GSLD).
Metrics
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
THIS IS AN OPEN ACCESS ARTICLE UNDER THE CC BY LICENSE http://creativecommons.org/licenses/by/4.0/
Plaudit
References
Sundararjan ,S. ,Narasimham ,K.C., and Udupa,V .K., “Electrolytic Preparation of Bromates”, Chemical and Process Engineering , September , P.438-441 (1962)
Clifford, A. Hampel, the Encyclopedia of Electrochemistry, Chapman and Hall, LTD. London, P.127-130, 1964.
Kirk-Othmer, Encyclopedia of Chemical Technology, 4th edition, Wiley Interscience Pub. New York, Vol.4, P.566- 567, 1992.
Downs , A. J. , and Adams ,C. J. , Comprehensive Inorganic Chemistry , Pergamon , Oxford , UK , Vol.2 , P.1400 , 1973.
Ewing,D.T.,and Schmidt,H.W.,Trans. Electrochemical . Soc. ,Vol.47 , P.117 , 1925 Kirk-Othmer, Encyclopedia of Chemical Technology , 3rd edition, Wiley Intersciece Pub . New York, Vol.4 , P.248- 249, 1984.
Kirk-Othmer, Encyclopedia of Chemical Technology , 3rd edition, Wiley Intersciece Pub . New York, Vol.4 , P.248- 249, 1984.
Talib A., “ Study The Factors Affecting the Cells of Sodium Chlorate Production ”, M.Sc.,Thesis, University of Baghdad, 2002.
Haman, C.H., “ Electrochemistry ”, 2nd edition , Wiley- VCH , New York , 1998.
Martin,C.H, and Hardy, E.C., U.S.Patent, 2,191,574 (1940)
Narasimham , K. C. , and Udupa , H.V.K. , “Preparation and Applications of Graphite Substrate Lead Dioxide (GSLD) Aonde ” , J . Electrochemical . Soc. Vol. 123, No.9, P.1294-1298, (1976). DOI: https://doi.org/10.1149/1.2133063
Internet, http://www.titanindia.com/ledga.htm/2005
Internet, http://www.wfvisser.dds.nl/EN/gsld_EN.htm/2005
AL-Kubaisy A.D, “Study The Factors Affecting the Cells of Sodium Perchlorate Production”, M.Sc.,Thesis, University of Baghdad, 2002.
T. Osuga and K. Sugino, J. Electrochemical.Soc., Vol.104, P.448, 1957. DOI: https://doi.org/10.1149/1.2428623
Vogel I. , Quantitative Inorganic Analysis , 3rd edition , Longmans (London) , P.343-350, 1961.