Effect of Electrolyte Concentration on Bubble Size and Gas-Liquid Interfacial Area in Bubble Column
Main Article Content
Abstract
The optimum conditions of bubble column would be the ones that enhance mass transfer and this is accomplished by maximizing gas-liquid interfacial area. In the present work the effect of electrolyte concentration (aqueous solution of sodium chloride NaCl 0.005-0.015 gm/cm3) on bubble size, gas-liquid interfacial area and gas holdup at various superficial gas velocities (0.35-0.312 m/s)) in bubble column was studied. A series of experiments were also performed for air – distilled water system at various superficial gas velocities. The results for the two systems were compared and show a significant difference on gas-liquid interfacial area, bubble size and gas holdup. Digital camera for bubble size measurements was used and the fractional gas holdup was estimated using bed expansion. Correlation based on dimensionless groups for the prediction of bubble size, gas- liquid interfacial area and gas holdup is suggested. An agreement with available data was found
Metrics
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
THIS IS AN OPEN ACCESS ARTICLE UNDER THE CC BY LICENSE http://creativecommons.org/licenses/by/4.0/
Plaudit
References
Parasu Veera, U. and Joshi, J.B., Trans IChemE, vol.78, Part A, 425-434, April 2000. DOI: https://doi.org/10.1205/026387600527329
Paras, S.V., Dalakoglou, G.K. and Mouza, A.A., Chem.Eng.Sci, vol.60, 1465-1475, 2004. DOI: https://doi.org/10.1016/j.ces.2004.10.013
Zahradnik, J., Fialova, M., Ruzicka, M., Drahos, J., Kastanet, F. and Thomas, N.H., Chem.Eng.Sci, 52, 3811- 3826, 1997. DOI: https://doi.org/10.1016/S0009-2509(97)00226-1
Camarasa, E., Vial, C., Poncin, S., Wild, G., Midoux, N. and Bouilliard, J., Chem.Eng.Proce., 38, 329-344, 1999. DOI: https://doi.org/10.1016/S0255-2701(99)00024-0
Joshi, J.B., Vitankar, V.S., Kulkarni, A.A., Dhotre, M.T. and Ekambara, K., Chem.Eng.Sci, 57, 3157-3183, 2002. DOI: https://doi.org/10.1016/S0009-2509(02)00192-6
Jamialahmadi, M. and Muller, S.H., Chem.Eng.Res. and Design, vol.68, A2, 202-204, 1990.
Zahradnik, J., Fialova, M., Kastanet, F., Green, K. and Thomas, N.H., Trans IChemE, vol.73, 341-346, 1995.
Akita, K. and Yoshida, F., Ind.Eng.Chem.Process Des.Dev., 1, 84-91, 1974. DOI: https://doi.org/10.1021/i260049a016
Akita, K., Int.Chem.Eng. , 29, 127-135, 1989. DOI: https://doi.org/10.3406/cea.1989.2139
Marrucci, G. and Nicodeno, L., Chem.Eng.Sci, 22, 1257-1265, 1967. DOI: https://doi.org/10.1016/0009-2509(67)80190-8
Prince, M and Blanch, H., AIChE.Journal, 10, 1485-1499, 1990. DOI: https://doi.org/10.1002/aic.690361004
Graig, V., Nigham, B. and Pashley, R., Letter Nasture, vol.364, 317-319, 1993. DOI: https://doi.org/10.1038/364317a0
Zahradnik, J., Kuncova, G. and Fialova, M., Chem.Eng.Sci, 54, 2401-2408, 1999.
Alves, S.S., Orvalho, S.C.P., Rodrigues, J.M.L, and Vasconcedos, J.M.T., Chem.Eng.Sci, 58, 1431-1440, 2003. DOI: https://doi.org/10.1016/S0009-2509(02)00675-9
Zuber, N. and Findlay, J.D., J.Heat Transfer Trans. ASME Ser.C, 87, 453-468, 1965. DOI: https://doi.org/10.1115/1.3689137
Shah,Y.T.,Kelkar,B.G.,Godbole,S.P.andDckwer,W.D.,AIC hE,28,353-379,1982 DOI: https://doi.org/10.1002/aic.690280302