Study The Effect of Glass Layers on Thermal Performance of Trombe Wall
Main Article Content
Abstract
The energy of solar intensity is very important in our life, not only for industrial and human needs, but also for living beings on earth. One of the advantages of solar intensity is using it in heating and cooling field in a number of activities among them the passive use. Thus can be done by using storage wall called (Trombe Wall). The effective of glass layers have been studies they are used to cover trombe wall from outside to measure its performance, selecting four conditions(i.e) (non-covering, single, double, and treble layers of glasses). The study shows that trombe wall in second condition with dimension (4x3x.29) m3 gives the best result in heating a room with dimension (4x4x3) m3. Under an environment condition of Baghdad city in Jan., 1994 in comparison with the other conditions. The average room temperature was approximately 26.75oC, it is among within included in average temperature allowable range (23- 27) oC. But the systems of heating in the third and fourth conditions have heat capacity higher than the demand; they can be adjusted to be suitable for their room if reducing the thickness of the wall until gives an among within included an average temperature allowable range .
Metrics
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
THIS IS AN OPEN ACCESS ARTICLE UNDER THE CC BY LICENSE http://creativecommons.org/licenses/by/4.0/
Plaudit
References
J. Richard Williams (1983) “ Passive Solar Heating ” AhnArbor Science publisher, pp. 1-13.
Trombe, F., J. R. Robert, M.Cabanat and B. Secolis (1976) “Some Performance Characteristics of the CNRS Solar HouseCollectors” in proceedings of the Heating and CoolingConference and Workshop, ERDA Report LA-6637-C, pp..222–201
Trombe, F., et al. (1975) “Some Performance Characteristics of the CNRS Solar Houses” in Transactions of the 1975 International solar Energy Congress (Newark, DE: American section, International Solar Energy Society) , pp. 366 – 367.
Balcomb, J. D., and R. D. McFarland (1978) “A SimpleEmpirical Method for Estimating the Performance of a Passive Solar Heated Building of the Thermal Storage WallType” in proceedings of the Second National Passive SolarConference, Passive Solar State of the Arts,Vol.2, (Newark, DE: American section, International Solar Energy Society), pp.377-389.
Akbari, H.,and T. R. Borgers (1978) “ Free Convective Laminar Flow Within the Trombe Wall Channel” LawrenceBerkeley Laboratory Report LBL-7802. DOI: https://doi.org/10.2172/6614331
Pratt, R. G., and S. Karaki (1979) “ National ConvectionBetween Vertical Plates with External Frictional Losses –Application to Trombe Walls” in proceedings of the ThirdNational Passive Solar Conference, Passive Solar State of the Arts,V ol.3,(Newark, DE: American section, International Solar Energy Society), pp.61-68.
جمال حميد وهيب “إستخدام الأملاح والشمع كمواد خزن حرارية في حائط ترومب” مجلة التقني, المجلد السابع عشر, العدد 1, 2004
Solar Energy Research Center, Solar Radiation Laboratory(1994) ”Solar Radiation and Collateral Weather Date forBaghdad City, January, 1994.
ASHRAE “Handbook of Fundamentals” ,2001.Chapter30,Email: [email protected].
Yunus A. Cengel (1998) “Heat Transfer A Practical Approach” WCB/ McGraw-Hill Co., pp. 303 – 320.
U.S. Department of Energy ,Energy Efficiency andRenewable Energy “Solar Heat Gain Control for Windows”, Content Last Updated05/04/2004.www.Eenergy%20Savers%20Solar%20 Heat%20Gain%20Control.
Pratt A. W. “Heat Transmission in Buildings” John Wileyand Sons Ltd. 1981.
Donald R. Pitts, and Leighton E. Sissom (1977) “Heat Transfer” Schaum’s Outline Series, Theory and Problems, McGraw-Hill-Book Co. pp.85-89 and pp. 201-204.
Khalifa A. J. N. , and R. H. Marshall “Validation of HeatTransfer Coefficient on Interior Building Surface Using a Real-Size Indoor Test Cell” Int. J. Heat Mass Transfer,Vol.33, No.10, pp.2219-1136, 1990. DOI: https://doi.org/10.1016/0017-9310(90)90122-B