The Dynamic Behavior and Control of the Methanol-Toluene Distillation Column
Main Article Content
Abstract
In this study, the dynamic behavior for two control methods of the distillation column for the separation of methanol and toluene mixture are studied. The experimental responses of temperature in each tray of distillation column for step changes in set point of reboiler, reflux ratio, and feed weight fraction are obtained. This is based on a derived mathematical model. Simulink simulator of the distillation column is used to implement the PID and fuzzy logic control methods. The comparison between the two controllers is done for step changes in set point, feed flow rate, feed weight fraction, and liquid reflux. The controller performance is measured depending on the mean square error and integral square error. The results show that the performance of the fuzzy controller is better than of the PID controller in fast access to the desired value and to cancelling the disturbances.
Metrics
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
THIS IS AN OPEN ACCESS ARTICLE UNDER THE CC BY LICENSE http://creativecommons.org/licenses/by/4.0/
Plaudit
References
Kano M, Showchaiya N, Hasebe S, Hashimoto I. Inferential control of distillation compositions: selection of model and control configuration. Control Engineering Practice 2003; 11: 927–933. DOI: https://doi.org/10.1016/S0967-0661(02)00215-0
Jana AK. Synthesis of nonlinear adaptive controller for a batch distillation. ISA Transactions 2007; 46: 49–57. DOI: https://doi.org/10.1016/j.isatra.2006.05.001
Filetia AMF, Antunesa AJB, Silvaa FV, Silveira V, Pereira JAFR. Experimental investigations on fuzzy logic for process control. Control Engineering Practice 2007; 15: 1149–1160. DOI: https://doi.org/10.1016/j.conengprac.2007.01.009
El-Garhy AM, El-Shimy ME. Development of decoupling scheme for high order MIMO process based on PSO technique. Applied Intelligence 2007; 26: 217–229. DOI: https://doi.org/10.1007/s10489-006-0015-1
Canete JF, Orozco PD, and Gonzalez S. Distillation monitoring and control using LabVIEW and SIMULINK tools. World Academy of Science, Engineering and Technology 2007; 34: 222-226.
Duraid FA, Mohammed HK. Studying of the dynamic behaviour and control of continuous distillation column. Tikrit Journal of Engineering Science 2013; 20 (4): 95-110.
Duraid FA, Maha NE. Fuzzy logic control of continuous stirred tank reactor. Tikrit Journal of Engineering Science 2013; 20 (2): 70-80. DOI: https://doi.org/10.25130/tjes.20.2.07
Duraid FA, Ahlam M S. Neural network control for a batch distillation column. Tikrit Journal of Engineering Science 2016;23 (1): 10-19. DOI: https://doi.org/10.25130/tjes.23.1.02
Mendel JM. Fuzzy logic systems for engineering: A tutorial. Proceedings of the IEEE 1995;83 (3): 345–377. DOI: https://doi.org/10.1109/5.364485
Mehmet K, Erhan A. Block based fuzzy controllers. IJRRAS 2010;3 (1).